CHARGING CONTROL BOARD CPU-6 ....
    Applicable models:YCT series three-phase charger
    Voltage range:12VDC、24VDC、36VDC、48VDC、72VDC、96VDC
    LED Display:LED light display, homogeneous charge (yellow), charging is completed (green), the last paragraph of charge (yellow), charging start (green), fault lamp (red)
    Features:
    ※by DIP switch setting voltage, selectable 12VDC, 24VDC, 36VDC, 48VDC, 72VDC, 96VDC.
    ※Built quick test function, can test the charger is functioning correctly.
    ※charging time can be set to the last paragraph, you can select 3.5 or 4 hours.
    ※choose manual or automatic start charging.
    ※Built-in rechargeable safety timing functions, when the charging time exceeds 16 hours or more automatically stop charging function (fault lamp direct light).
    ※Built-homogeneous charge function, when this function is activated, the battery will automatically start charging is completed, and the battery do ㄧ hours every homogeneous charge, the role of this function is to make each plate battery can be uniformly charged, and then extend battery life and operating time.
    ※built-in temperature signal contacts, when the charger overheating automatic stop charging function (fault LED flashes).
    ※can detect AC FAULE, DC FAULE, battery failure, and light display.

    ※Adjustable last paragraph of the charging current.